[2026-2-3 | Service Report] Resolving Low Flow from a Kitchen Water Purifier on Site
Service Log

[2026-2-3 | Service Report] Resolving Low Flow from a Kitchen Water Purifier on Site

Tplan

On February 3, 2026, after a resident reported weak water flow from the kitchen purifier, we visited the home to address the problem.

The inspection found sand, dirt, and limescale clogging the aerator (strainer) at the tip of the purifier faucet. This is a very common cause of poor water flow.

We removed the aerator—the plastic or metal mesh fitting at the faucet tip—and cleared debris with a toothpick and similar tools. We then soaked it in white vinegar for about 10–15 minutes to remove limescale, rinsed it thoroughly, and reinstalled it.

After the work, we confirmed that both the water volume and flow had returned to normal.

Water Flow Before Treatment

Water Flow After Treatment

Tplan